1KVA/0.9KW On-line Smart UPS, Tower
Model: KS-UDC9101H
Manufacturer: KSTAR
580.89 ₾
Add
In Stock
Warranty: 24 Month
Product Description
Documentation

Capacity (VA/W): 1000/900

Input
Rated Voltage: 100/110/115/120/127VAC or 200/208/220/230/240VAC
Frequency Range: Voltage Range: 55-145VAC or 110-300VAC
Frequency Range: 40Hz-70Hz(auto detect)
Power Factor: >= 0.99

Bypass Voltage Range:
Bypass high voltage point:
For 200/208/220/230/240 VAC models: 230-264: setting the high voltage point in LCD from 230VAC to 264VAC (default 64VAC)
For 100/110/115/120/127 VAC models: 115-132:setting the high voltage point in parameter 3 from 115 VAC to 132VAC (default: 132 VAC)

Bypass low voltage point:
For 200/208/220/230/240 VAC models: 170-220: Setting the low voltage point in parameter 3 from 95 VAC to 110 VAC (default:95VAC)
For 100/110/115/120/127/VAC models:95-110: setting the low voltage point in parameter 3 from 95VAC to 110 VAC. (default:95VAC)

ECO Range: Same as bypass
Generator input: Support

Output
Phase: Single phase & Ground
Rated Voltage: 100/110/115/120/127VAC or 200/208/220/230/240VAC
Power Factor: 0.9
Voltage Regulation: +/- 1%

Frequency:
Utility Mode: 47-53Hz (for 50Hz) or 57-63Hz (for 60Hz)
Battery Mode: 50/60Hz+/- 0.01Hz

Crest Factor: 3:1
THDv: <= 3% with linear load, <=6% with non linear load

Waveform: Pure Sinewave

Efficiency
ACMode (full load): >88%

Battery
Voltage: 24Vdc
Quantity: 2pc
Capacity(standard Unit): N/A
Backup: Long run unit depends on the capacity of external batteries
Recharge time to 90%: 4 hours
Charging Current (Built-in/Max.): 12A

Transfer Time
Utility to Battery: 0ms; Utility to bypass: <4ms

Prtection
Overload:
AC Mode: Ambient Temp.<35°C
-- 105%-110%: UPS shuts down after 10 minutes at battery mode or transfer to bypass when the utility is normal
-- 110%-130%: UPS shuts down after 1 minutes at battery mode or transfer to bypass when the utility is normal
-- >130%: UPS shuts down after 3 seconds at battery mode or transfer to bypass when the utility is normal

Bat.Mode 35°C < Ambient Temp.<40°C
-- 105%-110%:UPS shuts down after 1 minutes at battery mode or transfer to bypass when the utility is normal
-- >110%:UPS shuts down after 3 seconds at battery mode or transfer to bypass when the utility is normal

Bypass Mode:
-- 10A(input breaker)

Short circuit: Hold whole system
Overheat: Line Mode: Switch to Bypass; Backup Mode: Shut down UPS immediately
Battery Low: Alarm and Switch off
EPO(optional): Shut down UPS immediately
Battery: Advanced battery Managment

Alarms
Audible & Visual: Line Failure, Battery low, Overload, System Fault

Display
Status LCD: Line Mode, Backup Mode, Eco Mode, Bypass Low, Battery Bad, Oberload & UPS Fault
Reading On the LCD: Input Voltage, Input Frequency, Output Voltage, Output Frequency, Load Percentage, Battery Voltage

Physical
Dimension (WxHxD)mm: 144x209x293
Weight (kg): 4.1

Communication Interface
Communication Port: RS232 or USB
communication Slot: SNMP Card, Relay card,etc.

Environment
Operation Temperature: 0°C-40°CC
Storage Temperature: -25°C-+55°C
Humidity: 20-90% non condensing
Altitude: <1500m (derating while >1500m)
Noise: <50dB( at 1 meter)

Safety Conformance:
IEC/EN62040-1-1, IEC/EN62040-2